Exton, PA, Cooling Services
Are you ready for the summer heat and humidity? You need to ensure your air conditioner is operating correctly so you can make sure your family is cool and comfortable all summer. Call our experts at DiBiase Heating and Cooling Company for complete AC services in Exton, PA.
DiBiase Heating and Cooling Company offers 24/7 services to get your system up and running quickly. We provide complete cooling services to Exton, PA, and the surrounding areas, including:
- Commercial HVAC services
- Air conditioning repairs and maintenance
- Air conditioning installations and replacements
- AC filter replacements
- AC refrigerant leak repairs
- Smart thermostats
- Air handler services
- Ductless mini split AC services
- Evaporator coil services
AC Emergency Repairs: Why Your Air Conditioner Is Leaking
When you see moisture leaking from your air conditioner, it can be alarming. You might immediately wonder what the moisture is and what’s causing it. While some moisture can be expected, others can indicate you need emergency air conditioner services.
Some potential problems that can cause AC leaks are:
- A clogged condensate line.
- A rusty condensate pan.
- A dirty or frozen evaporator coil.
- A low refrigerant level.
- Dirty air filter.
It’s essential to call our experts for emergency AC repairs as soon as you notice moisture leaking from your system. The faster our DiBiase Heating and Cooling Company professionals can repair your unit, the sooner they will restore safety.
Expected Timeline for AC Installations
When you schedule air conditioner installations in Exton, PA, it’s essential to understand the process and how long the work can take to complete.
This will prepare you for what to expect during the AC replacement and how large of disruption it will be to your household. It also lets you prepare for how long you will be left without a working AC unit, as your house can be hot and uncomfortable.
The timeline will vary by project, but AC contractors estimate the installation can take 4 to 8 hours. This includes removing the old unit and getting the new one up and running.
Benefits of Installing a Ductless Mini Split AC System
When selecting a cooling system, there are numerous benefits to installing a ductless mini split AC system in your house. Some of the top advantages can include:
- A more energy-efficient unit that will help you reduce your energy bills.
- The ability to allow for zoning in your house, controlling the temperature in individual rooms.
- An easy installation process.
- Small, flexible designs that can be mounted on walls or ceilings.
- A quiet unit that makes less noise than a traditional forced-air unit.
- A unit that doesn’t require ductwork to transport the air.
Exton, PA, Heating Services
To keep your house warm and cozy all winter, getting your heater repaired quickly is essential. Call the heating contractors at DiBiase Heating and Cooling Company for emergency heater repairs in Exton, PA. We offer 24/7 services for your convenience.
Schedule services with a trusted professional when you need heater maintenance, repairs, or installations. DiBiase Heating and Cooling Company provides complete heating services to Exton, PA, and the surrounding areas, including:
- Thermostats
- Commercial HVAC services
- Heater repair and maintenance
- Heater installation and replacements
- Geothermal heating & cooling services
- Boiler services
- Heat pumps
Schedule Emergency Heating Repairs For Carbon Monoxide Leaks in Exton
There are many risks to running your heater in the winter months. While these can adequately keep your house warm, they also pose risks to your household.
One of the biggest threats is a carbon monoxide leak. Carbon monoxide leaks can happen suddenly. If this occurs, it can be incredibly dangerous for your family – even deadly.
In a heating system, combustion occurs in the heat exchanger, and air circulates around the outside of the unit. If there is a crack in the heat exchanger, then the combustion is incomplete, and it can create a carbon monoxide buildup. If this creates a leak, it can put your family at risk.
When you need emergency heater repair services, call our company for help. DiBiase Heating and Cooling Company provides the ultimate customer experience in Exton, PA. We guarantee 100% of your satisfaction!
Symptoms That Indicate You Need a New Heater
Do you need to replace your heater ? It’s essential to watch for key symptoms. Our experts recommend watching for the following signs:
- An aging unit: If your unit is nearing the end of its lifespan, it can be time to replace it.
- Rising energy bills: If your monthly utility bills are increasing, it can indicate your unit is working too hard to warm your home.
- Bad indoor air quality: If you’ve noticed more respiratory issues while you’re in your home or seen more dust piling up around your house, it can indicate your system is not adequately removing particles from the air.
- Uneven heating in your house: If you notice hot and cold spots around your home, it can indicate your unit is not efficiently heating your house.
- Odd smells: If you start to smell exhaust or foul odors, it’s time to replace your system.
Key Components in Your Heat Pump
Numerous parts of your heat pump perform essential functions. Some key components can include:
- Outdoor unit: The outdoor unit contains a coil and a fan.
- Indoor unit: The indoor unit, or the air handler, also includes a coil and a fan.
- Refrigerant: Refrigerant absorbs and rejects heat as it circulates through the system.
- Compressor: This pressurizes the refrigerant and moves it through the unit.
- Reversing valve: This changes the refrigerant flow, allowing the unit to switch between heating and cooling.
- Expansion valve: This regulates the flow of the refrigerant as it passes through the system.
How an Energy Audit Can Help You Save
An energy audit is a powerful tool to help homeowners in Exton reduce energy waste and lower utility bills. At DiBiase Heating and Cooling Company, our expert team conducts thorough audits to identify areas where your home is losing energy, such as drafts, poor insulation, and inefficient systems.
Once we identify problem areas, we provide tailored recommendations, including air sealing, insulation upgrades, and other energy-saving solutions. By addressing these issues, you can enjoy a more comfortable home while significantly cutting down on energy costs. Let DiBiase help you save money and improve your home’s efficiency today!
Should You Repair or Replace Your Water Heater?
Deciding whether to repair or replace your water heater can be challenging.
If your water heater is less than 10 years old and experiencing minor issues like inconsistent heating or small leaks, a professional repair may be the best solution.
However, if your unit is over 10-15 years old, frequently breaking down, or no longer meeting your household’s hot water needs, replacement is often the more cost-effective option.
Upgrading to a new, energy-efficient model can improve performance, lower energy costs, and provide reliable hot water for years to come. Contact DiBiase Heating and Cooling Company to assess your system and help you make the best decision for your home.
Which Water Treatment System Is Right for Your Home?
Choosing the right water treatment system depends on your home's specific needs.
Consider a whole-home filtration system if your water has an unpleasant taste, odor, or visible impurities.
For homes dealing with hard water issues—such as mineral buildup on plumbing fixtures and appliances—a water softener is an ideal solution to protect your home’s water system and improve water quality.
DiBiase Heating and Cooling Company offers both filtration and softening solutions, tailored to ensure your home receives the best possible water treatment. Contact us today to learn which system is right for you!
Recent Jobs and Reviews in Exton, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (2)
- Chadds Ford, PA (2)
- Chester Springs, PA (41)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (114)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (1)
- Devon, PA (1)
- Downingtown, PA (133)
- Eagleville, PA (3)
- East Fallowfield Township, PA (7)
- Elverson, PA (3)
- Exton, PA (43)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (21)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (23)
- Kennett Square, PA (19)
- King of Prussia, PA (3)
- Landenberg, PA (2)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (25)
- Media, PA (4)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (10)
- Parkesburg, PA (15)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (12)
- Ridley Park, PA (2)
- Royersford, PA (1)
- Saint Davids, PA (1)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (9)
- West Bradford Township, PA (22)
- West Brandywine Township, PA (3)
- West Chester, PA (73)
- West Grove, PA (2)
Job Locations and Reviews
Unit was in operation when I got here. Homeowner said he had to mess with vinyl on pump this morning. I turned off unit and went to remove pump to inspect it. The safety wires immediately fell apart and wire nut fell off. They had the orange wire nuts on them and not put together well. Stripped all wires and put on blue wire nuts. Added condensate tabs as well. Wired unit back up and tested operation. Pulled on condensate wires and shook pump. No issues. Seems like it was just a loose safety wire.
Completed heat tune up for 2 ton heat pump with 10KW electric heat kit. Aprilaire 401 filter in good condition. Humidifier pad in good condition. Checked operations. Inspected wiring and controls. Verified proper amp draw of 10KW heat kit. 40A Good. Outdoor equipment has surge protection. Indoor equipment does not. Left estimate for blower motor surge protector. After discussing, homeowner agreed to estimate. I completed work and tested today. Indoor and outdoor coils clean Inspected drain and EZ trap. Measured temperature rise and static pressure Verified integrity of compressor motor. Confirmed refrigerant charge/pressures System operating well at this time. Homeowner paid for plan renewal and EXM surge protector today.
Arrived for no heat we are just here yesterday and had told the customer that he would need electrician. The Electrician apparently found no problem with their side of power . I came out to look at the equipment. I had 120 V coming to the receptacle. I checked my wire nuts and the wiring at the furnace coming in from the receptacle and had no 120 volts . I took apart the 4x4 box For the switch and receptacle and found a very loose neutral from the furnace that was barely connected and causing arcing. I Stripped the neutral wire back put new wire nuts and tighten all connections . I Turned the system back on and tested the furnace , it came back on and and started producing heat. The system is back up and running at this time of service, no charge for recall.
Work on four suspended on the ceiling Reznor heaters. Three of them were not working. Checked operation of four of them. One had bad pilot installed new thermocouple. Another one pilot was out. Cleaned tubing and pilot. Reset unit and started heater. Third one had no 115 volt power to heater. Found breaker in the off position. Once breaker was reset unit came on. Test and cycle operation ok. All heaters are in working condition. We will need to finish cleaning/tune up on #5.
Performed QA on Trane Heat Pump/Air Handler install. Reviewed installation with homeowner. She mentioned that there was a noise coming from the return register in the hallway. She also mentioned that before her old system had low airflow everywhere and now some vents have a lot of air and other are still lower. When I went into the attic I checked all of the take offs and none of the, have dampers installed to adjust/balance airflow. Also found they used R-4 Flex in the attic instead of R-8. Checked the return filter grills and the filters need to be changed. Also found she is using MERV-10 or higher filters. Let her know to not use above MERV-8 filters and to see if that stops the noise. She is going to order new filters and change herself. Filter sizes are: 12x12x1 and 12x20x. Also let her know about the dampers and the ductwork in the attic. I recommended that she have all the ductwork reinsulated and new flex duct ran with dampers installed. She said she is fine for now with how th
Upon arrival Tom told me that he had an electrician here installing a dimmer switch yesterday. I came to unit and noticed furnace had power but no led. Traced out power and neutral. Found neutral with 120v in spots and 1.8volts in other spots it is back feeding from panel. If I pull neutral off board and jump n terminal to ground unit runs. I looked in panel and furnace is still hooked up to furnace breaker correctly. Need to have the electrician return from this point.
Installed new Bosch Airhandler on existing return box, reused existing return duct and filter rack. Installed a new supply plenum with a new flex collar. Insatlled new 10 KW heat kit. Installed new copper refrigeration line set from indoor coil to the outdoor unit. Installed new condensate with an ez trap and condensation pump, installed new vinyl tubing to discharge point. Installed new honey well t6 non Wi-Fi thermostat. Installed new Bosch heat pump on a new concrete pad, re-leveled the ground for concrete pad. Installed new disconnect box with a built in surge protector.
Took photos of equipment five Rasner suspended on the ceiling heaters and two package rooftop units gas/ac. Access to roof is from inside the building and has ladder hatch. Office to provide estimate. For service plans. Two people will be needed. Customer has forklift and cage to access hanging Heaters about 25 feet from ground.
removed old oil boiler and added new wall hung combi gas boiler, adapted to existing piping and re used existing circulator pump, zone panel, and thermostat, installed new auto fill and spiro vent and expansion tank, installed new domestic water lines with a new mixing valve, converted from gas to propane and ran new gas line and pressure tested it, ran 3/4 gravity drain outside, installed new 3” pvc piping for venting, cleaned work area and tested out.
Estimate
Performed heating maintenance on carrier heat pump. 201 filter replaced by homeowner. Static fine. Electrical wiring, connections and components Performed safety inspection on coil and drain could see some oil inside condensation pump, Cycled auxiliary / heat pump and both turn on. Condensing coil and refrigerant pressures fine. Electrical wiring, connections and defrost fine. Provided estimates and recommendations to homeowner. Unit is from 2009 would recommend getting an estimate to replace system. Office to follow up with customer.
Estimate
Gas furnace tuneup on a 90% Checked the air filter and found good customer just replaced . Checked the wiring connections and the voltages . Inspected and tested the burners and flame sensor and igniter. Flushed and tested the drain lines and furnace trap . checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. Inspected the flue pipe and fresh air for bellies. checked the motor amps on the inducer operation and blower motor . Took indoor heat temp rise and tested for combustion. everything is in good working order at this time of service.
Found no surge protection on indoor circuit board, installed zap pro surge protector. Also perform precision heat tuneup on train heat pump system. Replaced 16 x 20 x 1“ air filter. Check temperature rise. Check operation of emergency heat. Tested outdoor capacitor. Check refrigerant pressures and temperatures at indoor and outdoor units heat pump system is working fine at time of service.
Found no surge protection on blower motor, installed ECM surge protector. Also performed six month inspection on train heat pump system. 413 air filter is clean. Checked operation of emergency heat. Check temperature rise and heat pump heating mode. Checked all electrical connections and components. Check refrigerant pressures and temperatures at indoor and outdoor units. Heat pump system is working fine at time of inspection.
Performed heat tune up on Lennox heat pump. Replaced 16x20x1 air filter. Checked all electrical conections and components. Checked refrigerant pressures and temperatures at indoor and outdoor units. Checked operation of emergency heat 10kw ok Heat pump is working fine at the time of visit. Upon arrival found thermostat not responding, reset thermostat and still some times would not switch modes. Replace thermostat and test operation ok. Cycle heat pump ok.
Performed Tune up on amana heat pump, Ran unit and emergency heat mode and tested heat strips on the indoor unit as well as temperature split and blower motor, filter was changed as well. Went to the outdoor unit and inspected all electrical, mechanical components, including Refrigerant pressures and levels, And unit was tested in defrost and amps were taken on both motors as well as capacitor tested. No issues with unit at this time.
Performed tune up on amana heat pump, checked indoor unit and emergency heat mode and inspected heat strips and got a temperature split across the unit. Inspected the blower motor and the indoor coil as well as the humidifier and set the humidity dial to 35%, went to the outdoor unit and checked all electrical and mechanical components, including the compressor and outdoor fan motor as well as tested unit and defrost, and inspected the refrigerant pressures and levels. Capacitor was inspected as well as all of the associated wiring the outdoor unit, no issues with unit at this time.
Gas furnace tuneup on a 90% Checked the air filter and replaced. Checked the wiring connections and the voltages . Inspected and tested the burners and flame sensor and igniter. Flushed and tested the drain lines and furnace trap . checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. Inspected the flue pipe and fresh air for bellies. checked the motor amps on the inducer operation and blower motor . Took indoor heat temp rise and tested for combustion. everything is in good working order at this time of service.
Upon arrival for maintenance on gas furnace I checked air filter. I cleaned the flame sensor. I inspected heat exchanger and burners. I checked blower motor and assembly. I checked the resistance of igniter. Checked all wiring and control board. I checked inducer operation and ensured hose port was clear. Opened damper for humidifier. I went to turn on unit and the gas valve was stuck. I had to hit it with a wrench to get it to work. I turned on the unit in heat pump mode and checked delta t. Really recommend replacing gas valve. Gas valve closed prematurely before heating cycle. *****GAS VALVE NEEDS REPLACED******* Replace gas valve. Part only warranty.
Upon arrival for maintenance on gas furnace I checked the air filter. I changed the water panels for both systems. I cleaned the flame sensor. I inspected heat exchanger and burners. I checked blower motor and assembly. I checked the resistance of igniter. Checked all wiring and control board. I checked inducer operation and ensured hose port was clear. I checked gas pressures. Checked air temperature rise. Performed combustion test. Tested operation of both humidifiers. Unit is in normal operation at this time. Replacing standard burners that are under parts warranty. We are ordering the burners and Herman is ordering two ecobees to replace his nest with. We need to communicate with him so we can do burners and tstats at the same trip. He requested I be the one to come back.
Upon arrival for heat maintenance on heat pump tune up I changed the filter. Checked electrical and wiring and emergency heat kit. Checked blower motor and assembly. Checked delta t. Inspected coils. Checked fan motor and assembly. Checked refrigerant pressures via inverter board by hertz. Forced unit into defrost. Unit is in normal operation at this time.
Performed tuneup on heil gas, furnace, ran system and heating mode and tested combustion as well as checked gas pressure and all related ignition components upon performing combustion analysis. I noticed the parts per million of carbon monoxide were abnormally high doing some investigative work I found entirely too many turns in the vent system, not allowing proper airflow through the inducer motor customer was notified and he said he will contact the person who put in the furnace and they will come out and fix it. Everything on the furnace checked out well no other issues we have to come back next week in order to do combustion analysis wants the repairs made to ensure the unit runs correctly.
Mini split tuneup on 2 heads and one outdoor. Checked the air filters and cleaned. Checked the wiring connections and the voltages. Inspected the unit and the blower operation cleaned if necessary. Check the fan operation for all speeds and checked the unit in the heating mode operation. Took temps from return side and supply. Checked the outdoor heat pump, wiring connections, and the voltages. Checked the combined amps for the fan and the compressor. The indoor heads and the outdoor heat pump or in good working order. She was having a small issue , but the remotes were on different settings causing the heads not to communicate. The tune ups were completed today , can cancel her scheduled maintenance in 2 weeks .
Performed tune up and cleaning on Weil McLain oil fired boiler. Disassembled entire boiler and brushed and vacuumed heat exchanger and entire chimney base, replaced filter, nozzle and strainer. Primed entire oil system and performed combustion analysis. Checked over entire system for leaks and ensured the aquastat shut off at desired set point. No issues with boiler at this time.