Coatesville, PA, Cooling Services

Is your air conditioner no longer keeping your house cool? You need to schedule repairs or replacements as soon as possible. Call DiBiase Heating and Cooling Company for appointments in Coatesville, PA. We offer on-time services!

Our experienced technicians can diagnose the problem, repair it, and recommend a replacement if needed. DiBiase Heating and Cooling Company provides complete cooling services to Coatesville, PA, and the surrounding areas, including:

  • Commercial AC services
  • AC filter replacements
  • AC refrigerant leak repairs
  • Air conditioning repairs and maintenance
  • Air conditioning installations and replacements
  • Air handler services
  • Ductless mini split AC services
  • Smart thermostats
  • Evaporator coil services

After-Hours AC Repairs in Coatesville

When you experience an electrical issue with your air conditioner, it can require emergency AC repairs. These can pose dangerous threats to your household, including electrical fires, and leave you without a working air conditioner. This is especially problematic if it’s hot out.

You need to call for emergency air conditioning services at your house in Coatesville, PA. While waiting for the expert to arrive, there are some steps you can take on your own, including checking the circuit breaker to see if it tripped and if that’s what’s causing the problem.

When an AC contractor arrives, they will inspect the wiring and other electrical components to diagnose and repair the issue. DiBiase Heating and Cooling Company is available 24/7 for your convenience and peace of mind

What To Know About New Air Conditioners

When you schedule central air conditioning installations, your focus might be on the work being done to get the new unit up and running. However, it’s just as important to know what to expect with a newer, more modern model.

For one, newer units are larger than older systems. These can be 20-50% bigger in height, length, and width than older models. To fit the new system, technicians may need to relocate your new system or enlarge the spot.

Doing this might require you to move your ductwork or adjust it. It might also increase the timeline and budget of the installation. However, this is usually something you are made aware of before the day of the installation.

If you have questions or concerns about your AC installation, call DiBiase Heating and Cooling Company!

When to Call Experts for Ductless Mini Split AC System Repairs

When your ductless mini split AC system malfunctions, you might wonder if you need to schedule professional repairs or if you can handle the work on your own.

Depending on the issue, you can fix the problem yourself. Before calling an expert, you can check the air filter to see if it needs to be replaced, ensure the thermostat is set to “Cool,” and make sure a circuit breaker didn’t trip.

If these troubleshooting tips do not resolve the issue, you should schedule professional cooling repairs in Coatesville, PA.

Coatesville, PA, Heating Services

When your heater malfunctions and you need emergency repairs or replacements, you need to schedule emergency services with an experienced, trusted local heating company. Call DiBiase Heating and Cooling Company for appointments in Coatesville, PA. We offer 24/7 services!

We provide complete heating services to Coatesville, PA, and the surrounding areas, including:

  • Commercial Heating services
  • Heater repair and maintenance
  • Heater installation and replacements
  • Geothermal heating & cooling services
  • Thermostats
  • Boiler services
  • Heat pumps

Why a Broken Thermostat Is a Heating Emergency

With a fully functioning thermostat, your central heating system can work properly. If your thermostat malfunctions, you might consider this a minor problem. However, it requires emergency heating repairs.

While waiting for a heating contractor to arrive, there are steps you can take to troubleshoot the issue. These can include first checking if the thermostat is correctly set to Heating. If it’s set to Cool, then you can switch it. This should correct the problem.

Next, you should check the device’s batteries. Make sure these are working. If not, then replace them. You should also ensure nothing is blocking the thermostat, preventing it from adequately reading the temperature in the room.

Signs Your Heating System Is Failing

It’s essential to schedule heater replacements at the first signs that your system is malfunctioning. It’s also important to recognize which symptoms imply repairs versus which ones can indicate you need to install a new system.

One of the most obvious signs is if your house is no longer heating to the desired temperature. While this could be an issue with your thermostat, it’s crucial to have a technician inspect your unit, as it can also indicate your system is failing.

Other symptoms to watch for include if your unit is making odd noises or if your utility bills are suddenly increasing. This can indicate your system is losing efficiency.

If you notice any of these problems, call our experts at DiBiase Heating and Cooling Company for heater repair services, inspections, and replacements. We provide the ultimate customer experience in Coatesville, PA, and beyond.

Importance of Scheduling Heat Pump Maintenance

It’s crucial to schedule annual maintenance services on your heat pump to keep it working correctly. These routine tune ups allow heating contractors to conduct a complete system inspection and look for defects that must be repaired.

Performing these services also helps improve the unit’s performance, making it more energy-efficient and prolonging the life expectancy of the system.

Home Energy Audits

A home energy audit is a detailed inspection that identifies areas where energy might be wasted in your home, such as through drafts, insulation gaps, or inefficient appliances. By targeting these problem areas, we can make recommendations to boost efficiency, reduce utility costs, and increase overall comfort.

Signs that your home might benefit from an energy audit include uneven temperatures, high energy bills, or noticeable drafts. Once the audit is complete, our team offers customized solutions—like air sealing and insulation improvements—to enhance your home’s energy performance.

Water Heater Repair and Replacement

Water heater repairs are typically needed when you notice leaks, unusual noises, or insufficient hot water; these issues can often be resolved to restore functionality. Replacement becomes a more cost-effective choice if your unit is over 10-15 years old, breaks down frequently, or no longer meets your household’s hot water needs.

We service both tank-style and tankless water heaters, offering expert repairs and replacements for each type. Upgrading to a new, energy-efficient water heater not only ensures reliable hot water but can also reduce your energy costs and provide improved performance.

Water Treatment Solutions

A whole-home water filtration system provides clean, filtered water from every tap by removing contaminants such as chlorine, sediment, and other impurities. Adding a water softener can further benefit your home by reducing water hardness, which helps prevent mineral buildup in plumbing and appliances while also improving water quality.

Common signs that water treatment may be needed include hard water spots, mineral deposits, or an unpleasant taste or odor. We offer comprehensive water treatment solutions, including whole-home filtration and softening systems, customized to fit your home’s specific needs.

Recent Jobs and Reviews in Coatesville, PA

Rated 4.9 out of 5 stars based on 113 customer reviews

Job Locations and Reviews

Barry P.
Barry P. Checked in
Found extinguished pilot at 75,000 BTU natural gas furnace located in attic above drop ceiling at the end of hallway apartment. Ultimately determined Failing thermocouple and clogged pilot tubing. The blower door is taped because this is not the original blower motor an protrudes beyond the frame of the furnace. This makes it very difficult service and even relight the pilot. I replaced thermocouple and clamps pilot bunt and assembly. The furnace cycled on and off several times however the pilot did randomly shut off once. The gas valve is in the process of failing. Equipment is from 1991. If thenanta call in with a no heat issue the solution is to replace the furnace. System is operating when I left but is likely to shut off at some point. I had final conversation with Carolyn and she would like a consultation for system upgrade quote ASAP. Our staff will be in touch with Carolyn to set up appointment. *I also added a 20x20x1 filter to the ceiling rack. System has been runn
Coatesville, PA 19320
Bill D.
Bill D. Checked in
.
Coatesville, PA 19320
Tim M.
Tim M. Checked in
Upon arrival I went through thermostat and checked alert history. Was only 185.05 compressor lubrication. This is more of a notification than an error. No issues there. I went into attic and had 66° return and 105° supply with no emergency heat. I went to outdoor unit and checked pressures. Pressures are normal. No fault codes on indoor or outdoor boards. Thinking noise is defrost cycle. System is in normal operation at this time.
Coatesville, PA 19320
Barry P.
Barry P. Checked in
The sound that they were concerned about is the normal operating sound of the new condensate pump. A high efficiency furnace will produce anywhere from 5-7 gallon of water per day and there is a humidifier so pump will energize throughout the day. Went over this with Kevin. System operating well at this time.
Coatesville, PA 19320
Barry P.
Barry P. Checked in
Completed heat tune up for 80,000 BTU 2 stage gas furnace: 20x25x4 filter ok Inspected burners, heat exchanger, inducer assembly pressure switches Cleaned flame sensor and verified flame rectification circuit. Measured ignitor ohms; in good condition Inspected wiring, controls, electric motors and verified fan speed settings; left estimate for blower motor surge protector Measured temperature rise and static pressure AC drain does not have overfill protection or a clean out. I left estimate for EZ trap. Combustion and draft tests: Pass System operating well at this time.
Coatesville, PA 19320
Tony F.
Tony F. Checked in
Estimate
Coatesville, PA 19320
Kurt  M.
Kurt M. Checked in
Fully assessed no heating situation. Found system locked out on error codes. Took photos of the error codes. Explain to homeowner that a lot of times these error codes are due to a change in the power coming into the home. Showed homeowner how to reset indoor breaker and outdoor heat pump breaker. Ran system in test mode for both heat pump at 100% and second stage gas furnace. Perform combustion test. Hybrid system is working fine again at time of service.
Coatesville, PA 19320
Barry P.
Barry P. Checked in
Completed 6 month inspection for 100,000 BTU natural gas furnace. Replaced 16x25x1 filter Inspected burners, heat exchanger, inducer assembly Cleaned flame sensor, verified flame rectification circuit Ignitor in good gondorion: ohm reading Good Confirmed proper manifold gas pressure Inspected wiring, controls, electric motors and fan speeds. Checked drains Measured temperature rise and static pressure. Combustion and draft tests: Pass System working well at this time. I did discuss humidifier and left estimate for limits promotional pricing. He is not interested right now.
Coatesville, PA 19320
Review
Barry provided excellent care during the routine maintenance of my service
Dennis - Coatesville, PA 19320
Barry P.
Barry P. Checked in
Completed heat tune up: Lennox gas furnace Replaced 16x25x1 filter Inspected burners, heat exchanger, inducer assembly Cleaned flame sensor, verified flame rectification circuit Ignitor in good condition, ohms reading Good Confirmed manifold gas pressure Measured temperature rise and static pressure Inspected wiring, controls, fan speeds; left estimates for (2) differential kinds of surge protectors. Thermostat is on wall opposite oven which influences performance and comfort. I left estimates for smart thermostat with room sensor, Checked drains; discussed and left estimates for EZ trap and wet switch, Combustion and draft tests pass System operating well at this time,
Coatesville, PA 19320
Barry P.
Barry P. Checked in
Miller oil furnace for double wide trailer. The door switch was off which stops power to oil burner. There was a piece of tape there to keep this switch closed, but it had made its way lose. I put new tape there. However I found that if you push the top left corner in it will keep switch engaged. Combustion test ok System is operational at this time. Left estimate for oil heat tune up.
Coatesville, PA 19320
Review
Excellent Service
James - Coatesville, PA 19320
Luis T.
Luis T. Checked in
Oil furnace is not working found primary locked out on ignition. Use contractor tool from Beckett to troubleshoot unit. Found last two cycles did not light. Check oil, flow pump pressure 110 psi inspect nozzle and electrodes. Found nozzle to be clogged preventing oil flow to the burner ignition zone. Replace nozzle test operation re-adjust electrodes and perform combustion test recycle furnace six times and all six times unit came on with no issues cad cell reading average is 320 on every cycle. Combustion test ok no charge warranty
Coatesville, PA 19320
Barry P.
Barry P. Checked in
Found that vinyl tubing (condensate discharge) had frozen causing the pump safety to open and shut system down. I ran new vinyl tubing and installed barb in plumbing. Secured new tubing and tested system. System operating well at this time.
Coatesville, PA 19320
Zachary  B.
Zachary B. Checked in
*Did not have r32 to fully charge. Check charge and adjust at later date.* Set unit in place on furnace feet. Adapted to Supply duct work and installed new return drop with aprilaire 2410 filter. Ran new line set from indoor unit to outdoor unit. Ran new condensate drain to gravity drain with new eztrap safety switch. Made all high and low voltage connections to unit. Adapted to existing vents. Set new unit on new pad and leveled. Installed new disconnect with internal surge protector and sealed to wall. Piped lineset into unit. Brazed pressure tested evacuated and charged unit. Made all high and low voltage connections to unit. Performed test out procedures cleaned all work areas and reviewed installation with homeowners.
Coatesville, PA 19320
nathanfh03@gmail.com
nathanfh03@gmail.com Checked in
Installed new Gas Piping in the basement to the area where the Dryer will be located. Tapped into the existing gas piping in the basement. Ran Flexible Gas Pipe through basement (35' - 40'). Install Floor Flange behind dryer area with Shut Off Valve. Cap the Gas Line in preparation for the dryer to be installed and connected. Turn the Gas Supply on and test all connections for leaks. Final connection from the Dryer to the Gas line to be completed by the Dryer installation company.
Coatesville, PA 19320
Barry P.
Barry P. Checked in
There was small amount of water in equipment pan. It had caused wet switch to open. Homeowner had reset the switch before I got there. I first opened both furnace compartments and there was no water on either. There was a small pool of water in one corner of return drop. I ran humidifier for 5 min and furnace for 8 min to try to cause leak to recur/ find source of water. Ran system and humidifier several time as to try to identify source of leak. Leak did not show itself. There is a n appliance connector at furnace gas piping to the gas valve. This should be redone in 1/2” black iron piping. Will give (2) separate estimates (1) get rid of appliance connector at gas piping and replace with 1/2” black iron. OR (2) Re pipe gas (propane) line so that it falls behind the humidifier bypass duct. This will involve shutting off propane to the house and then making sure gas fire place and stove a relit afterwards. System operating well.
Coatesville, PA 19320
Joseph D.
Joseph D. Checked in
Reviewed air temperature rise from oil furnace. Found to be set at 40 degf after 10 mins runtime. Lowered fan speed to red wire , low fan speed setting and remeasured at 54 degf , max temp rise is 70 degf for furnace. Supply temp at 127, return temp at 73 degf. Temperature will drop in pipe in crawl space until crawl is sealed. Supply Air temperatures are relative to return air temperature.
Coatesville, PA 19320
Nathan P.
Nathan P. Checked in
.
Coatesville, PA 19320
Nathan  B.
Nathan B. Checked in
Performed 6 month inspection on gas furnace. Checked unit in heating mode and tested combustion and gas pressure in both high fire and low fire, tested blower motor and inducer motor in both modes and tested temperature rise and air filter. Flame sensor was cleaned and checked and hot surface igniter. No issues with unit at this time. Customer states she is having trouble cooling the upper floors and would like a quote on a mini split system for the upper floors. Air filter size is aprilaire 413 .
Coatesville, PA 19320
Kurt  M.
Kurt M. Checked in
Perform precision heat tuneup on 2018 train high-efficiency gas furnace. Homeowner just replaced 210 high-Efficiency air filter. Also 35 humidifier pad is clean. Found quarter inch tapping that feeds humidifier is very corroded at valve provided estimate to replace with newer shark bite style quarter inch tapping. Also found no wet switch installed in case humidifier would leak on the floor to shut down system Provided estimate for wet switch. Clean flame sensor. Blew out drain tubing. Tested condensate pump. Checked temperature rise. Performed combustion test. Gas furnace is working fine at time of service.
Coatesville, PA 19320
dillon@dibiasehvac.com
dillon@dibiasehvac.com Checked in
System design.
Coatesville, PA 19320
Luis T.
Luis T. Checked in
No hot water, found rheem atmospheric 50 gallon water heater off upon arrival. Violet it out, tried to relight the pilot pilot states on turn thermostat to regular temperature and noticed flames bouncing. Removed pilot and clean assembly inspect indoor condition notice some areas that are wet. Check chimney base OK try to relight pilot once again and the burner came on still flames bouncing. Water heater needs new assembly and new temperature valve. there is a small leak, from the a rod fitting on top of the water heater. Current water heater is from 2016 provider an estimate to replace water heater. Customer decided to replace water heater. Customer also paid 50% down for the replacement office to follow up with customer tomorrow morning.
Coatesville, PA 19320
Luis T.
Luis T. Checked in
No heat situation. Customer thinks the heater stopped sometime last Friday night. Found unit off upon arrival inspect heater check blower motor and wheel started heater found inducer assembly wheel broken in pieces. Performed visual inspection on parts that could be check without furnace running. All ignition parts are below standards. Heat exchanger is showing lot of corrosion and rust. Unit is from 2005. Provided estimate for necessary repairs. Once we get unit running we will perform combustion analysis and safety test on entire unit. Would recommend getting an estimate to upgrade system before we perform any repairs. Home comfort consultant to come later on today.
Coatesville, PA 19320
Luis T.
Luis T. Checked in
Gas heat tuneup, check electrical low and high voltage connections, clean flame sensor inspect igniter check low and high stage. Perform combustion test check supply and return our temperatures. Check static pressure on full system inspect pressure tubing. Test safeties ok. Cycle gas heater ok. Talk to Christine on potentially adding a whole house humidifier customer will think about this addition in near future.
Coatesville, PA 19320
Tim M.
Tim M. Checked in
Venting is too long for 2” or should have been 3”. There are 7 short throw 2” 90s and a low profile concentric kit. Total of 8 90s. Maximum allowance with 8 is 40 feet. Goes from basement up to first floor ceiling and out of back of house. Totaling about 50-55 feet. Could possibly switch all possible 90s to 45 and do a normal termination outside. Or run new venting on basement ceiling out of back of house. Side of house may be better.
Coatesville, PA 19320
Tim M.
Tim M. Checked in
Upon arrival Diane showed me the low water cutoff light flashing. Checked all valves and all was open. Checked water pressure gauge and it read 22 psi. Put on a separate water pressure gauge to make she that one wasn’t failed and giving a false reading. Other gauge said 22 psi as well. Reset system and it turned on. Tested low water cutoff. Function was normal. Diane mentioned she’s been having power spikes. Could be possible cause.
Coatesville, PA 19320
Review
Outstanding service. Corrected previously undetected installation issues. Thorough and methodical.
DC - Coatesville, PA 19320
Review
Excellent service
James - Coatesville, PA 19320
Review
Excellent service
James - Coatesville, PA 19320
Review
Awesome customer service with representative I spoke with and my technician Tim was awesome, handled my issue swiftly and efficiently
Myra - Coatesville, PA 19320
Review
Excellent service
Arthur - Coatesville, PA 19320
Review
Excellent presentation and explanation the service proposal - Tony is knowledgeable and is able to explain technical jargon in practical terms. He go
Arthur - Coatesville, PA 19320
Review
Personable, good attitude,knew his job,very professional.
James - Coatesville, PA 19320
Review
Barry went above and beyond the service/maintenance call to provide useful information and explanation about HVAC maintenance and followed up with recommendations and options to consider for the efficient operation of my HVAC systems.
Arthur - Coatesville, PA 19320
Review
Excellent and knowledgeable
Arthur - Coatesville, PA 19320
Review
Excellent Service
Kim - Coatesville, PA 19320
Review
Tim was courteous, easy to work with and performed the service as requested. Always appreciate the DiBiase teams understanding and handling of our service requirments.
Chris - Coatesville, PA 19320
Review
Nathan was on time and scheduled the service we need for our a/c unit
Mike - Coatesville, PA 19320
Review
I really appreciate Luis, he is very personable and does a fantastic servicing job.
John - Coatesville, PA 19320
Review
They sent someone out at 10pm to address our issue. He patiently explained everything. (my husband was at work) Was more than satisfied.
Kim - Coatesville, PA 19320
Review
Barry is my preferred technician. Answered questions regarding some steps I can take to ensure my AC system stays healthy and working properly and performed the annual Fall tune-up for the Winter.
Chris - Coatesville, PA 19320
Review
Luis is punctual, courteous, and honest! We wouldn’t have anyone else maintaining our system. He also cares about us personally.
John - Coatesville, PA 19320
Review
Great service!
Lauren - Coatesville, PA 19320
Review
On time, friendly, put in an overflow valve if discharge pipe clogs. told me I had a small roof leak. I have a bi-annual service contract , they call me to make appointment.
John - Coatesville, PA 19320
Review
Tim was great, thank you!!
January - Coatesville, PA 19320
Review
The technicians are thorough and professional.
Timothy - Coatesville, PA 19320
Review
On time, great job, knowledgeable, courteous
Neal - Coatesville, PA 19320
Review
Barry is ALWAYS courteous and potential and I was thrilled to find out he was coming out for the on-call appointment!! He is always thorough and also always conscientious on explaining what the issue is (and how to potentially resolve and/or trouble shoot for future incidents)!! Thanks so much, Barry and DiBiase for the consistent, professional and timely service!!!
Michael - Coatesville, PA 19320
Review
Came in and discovered a problem and resolved it immediately!
Lucy - Coatesville, PA 19320
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next