Bayboro NC Heating & Air Conditioning Services
Jackson and Sons has provided full-service residential and commercial heating and air conditioning installation, maintenance tune-ups and repair services in Bayboro, NC since 1974.
Read our reviews to learn why your neighbors call us first for their home and business comfort needs in Bayboro, NC, then call us at 919-734-9611 to see what we can do for you.
Local Reviews
for Bayboro, NC
Customers say: The recent reviews exhibit a positive overall sentiment, with a slight inclination towards the positive. The reviewers express satisfaction with the services provided, highlighting the helpfulness, expertise, and professionalism of the technicians. They mention the timeliness, efficiency, and quality of the work done. Additionally, the reviewers appreciate the courteous and respectful behavior of the technicians, as well as their willingness to answer questions and provide detailed explanations. The positive reviews also mention the positive experiences with the company's customer service, including the ease of scheduling appointments, the clarity of the pricing, and the overall positive impression left by the technicians. However, it's worth noting that the negative reviews are fewer in number and do not contain any significant negative sentiment. Overall, the reviews suggest that customers have had positive experiences with Jackson and Sons and would recommend their services to others.
Our Reviews by City
Great Service
Susan - Bayboro, NC 28515
Always great service
Great Service
Susan - Bayboro, NC 28515
Always Great service
Great Service
Bayboro - Bayboro, NC 28515
Always great service

David S.
-Performed CMA Full Service on 3 Split Heat Pumps. -System 3 - 2018 Trane 4 Ton Split Heat Pump: Right Side of Space from Front: Outdoor fan motor capacitor tested weak. Recommend replacement of capacitor. Provided estimate for replacement of 7.5 mfd capacitor. Customer approves replacement of capacitor.

David S.
-Performed CMA Full Service on 1 Trane Split Heat Pump at left parcel. -System 5 - 2019 Trane 3 Ton Split Heat Pump - Left Parcel: Observed flash code 2 (coil temp sensor out of range), 7 (timed defrost mode), 8 (timed defrost mode) upon arrival. Found coil temperature sensor resistance is not within range for actual temperature. Recommend replacing coil temperature sensor. Provided estimate for replacement of sensor.

David S.
-Performed CMA Full Service on 1 Trane Split Heat Pump at middle parcel. -Sustem operating without challenge at this time.

Aidan T.
{System #3} - Tech found thermostat calling for cool upon arrival, but outdoor unit not running. Contactor received 24v call and pulled in contacts. 240v power is present on line side but not on load side. - Replaced contactor and confirmed refrigerant charge and operation. - Outdoor ambient temp sensor was out of range causing a single flash code on defrost control. Tech reset the sensor and cleared code. - Advised customer that both capacitors are slightly weaker than their correct ratings. System is operating normally at this time. Thermostat set to 72 at tech departure.

Noah C.
Tech returned to replace blower motor/module. Tech tested system operation after new motor/module installation. System is back up and cooling, pressures are within spec.

Noah C.
Upon arrival tech found condenser 3 in a hard lockout due to multiple low pressure lockouts. Tech reset system and found suction pressure immediately drops upon startup. Tech inspected air handler and found blower not running. Tested module and found it to be receiving 240v as well as a 24v call. Motor and module have failed. Need to order motor and module and schedule repair.

Wes B.
Performed a full service maintenance on a Trane heat pump, changed filters, washed coils and unit, tested heat strips, blower, capacitors, amps, cleared drain traps, checked T-stat.

Wes B.
Performed a full service maintenance on a Trane heat pump, changed filters, cleared trap, tested heat strips, capacitor, blower motor, checked T-stat. Washed coils and unit.

Wes B.
Performed a full service maintenance on 3 Trane heat pumps, changed filters, tested motors, heat strips, capacitors, cleared drain traps, washed coils and units. Checked T-stats.

Luis R.
Full service on 5 Trane heat pumps.